Access product manuals, instructions, and safety guidelines for all Nice Neotech devices. Download the latest IFU documents to ensure proper usage and maintenance.
Orchid
nice 3000 is an infant transport incubator designed to provide a stable, thermally controlled, and protective environment for newborns during intra-hospital and inter-hospital transport. Built with advanced temperature regulation, monitoring systems, and secure infant positioning, it supports safe and continuous neonatal care even during movement, ensuring comfort, safety, and clinical reliability.
Infant Incubator provides a closed, controlled environment that warms the baby by circulating heated air over the skin. By creating the temperature range required for the newborn, the equipment protects them from infection, air drafts and handling by nurses. This NICU equipment also delivers humidified oxygen to the neonates.
nice 3010 – Wallaby is a next-generation neonatal care solution designed to provide a stable, thermally controlled, and nurturing environment for critically ill and premature newborn. Built with advanced temperature regulation, optimal humidity control, and caregiver-friendly access, it supports superior clinical outcomes while ensuring comfort, safety, and reliability in the NICU
Infant Incubator provides a closed, controlled environment that warms the baby by circulating heated air over the skin. By creating the temperature range required for the newborn, the equipment protects them from infection, air drafts and handling by nurses. This NICU equipment also delivers humidified oxygen to the neonates.
nice 3010 – Wallaby is a next-generation neonatal care solution designed to provide a stable, thermally controlled, and nurturing environment for critically ill and premature newborn. Built with advanced temperature regulation, optimal humidity control, and caregiver-friendly access, it supports superior clinical outcomes while ensuring comfort, safety, and reliability in the NICU
nice 3000 is an infant transport incubator designed to provide a stable, thermally controlled, and protective environment for newborns during intra-hospital and inter-hospital transport. Built with advanced temperature regulation, monitoring systems, and secure infant positioning, it supports safe and continuous neonatal care even during movement, ensuring comfort, safety, and clinical reliability.
nice 5060 F Bubble CPAP System is a neonatal respiratory support solution designed for spontaneously breathing newborns requiring continuous positive airway pressure. Using an integrated air and oxygen flow meter manifold with a bubble-generated PEEP mechanism, the system delivers stable airway pressure to support alveolar recruitment, prevent lung collapse, and reduce the work of breathing.
nice 9020 is an advanced adult ventilator engineered to provide accurate and consistent respiratory support for patients requiring assisted ventilation. It delivers controlled airflow and oxygen delivery to support effective breathing, helping clinicians manage a wide range of respiratory conditions with confidence and stability.
nice 9010 is a versatile ventilator engineered to provide consistent and controlled ventilation for both neonates and pediatric patients. It supports a wide range of clinical needs with accurate pressure and volume delivery, ensuring safe and effective respiratory management while maintaining patient comfort and stability.
nice 9000 is an neonatal ventilator designed to deliver precise and reliable respiratory support for infants requiring assisted ventilation. Engineered with accurate pressure and volume control, it ensures stable breathing support while prioritizing infant safety, comfort, and clinical efficiency in critical care environments.
nice 9020 is an advanced adult ventilator engineered to provide accurate and consistent respiratory support for patients requiring assisted ventilation. It delivers controlled airflow and oxygen delivery to support effective breathing, helping clinicians manage a wide range of respiratory conditions with confidence and stability.
nice 9010 is a versatile ventilator engineered to provide consistent and controlled ventilation for both neonates and pediatric patients. It supports a wide range of clinical needs with accurate pressure and volume delivery, ensuring safe and effective respiratory management while maintaining patient comfort and stability.
nice 9000 is an neonatal ventilator designed to deliver precise and reliable respiratory support for infants requiring assisted ventilation. Engineered with accurate pressure and volume control, it ensures stable breathing support while prioritizing infant safety, comfort, and clinical efficiency in critical care environments.
nice 5060 F Bubble CPAP System is a neonatal respiratory support solution designed for spontaneously breathing newborns requiring continuous positive airway pressure. Using an integrated air and oxygen flow meter manifold with a bubble-generated PEEP mechanism, the system delivers stable airway pressure to support alveolar recruitment, prevent lung collapse, and reduce the work of breathing.
nice 5040 – Engineered for dependable oxygen monitoring, the Oxygen Analyser employs an electrochemical sensor that delivers accurate, low-drift measurements with minimal power consumption. Its resistance to interfering gases and reliable detection performance make it a trusted, cost-effective solution for clinical oxygen concentration assessment.
The Oxygen Hood (Head Box) is engineered to deliver a controlled oxygen-rich environment for neonates, infants, and paediatric patients requiring respiratory support. Its clear, ergonomic design allows continuous patient observation while ensuring gentle and uniform oxygen administration for enhanced comfort and clinical confidence.
The Electrical Slow Suction unit is designed to provide controlled low-flow suction using negative pressure, making it ideal for gentle aspiration of fluids and secretions in respiratory management. Engineered for clinical workflows, this electrically powered system ensures consistent performance with quiet operation and dependable suction, supporting effective airway clearance in sensitive care settings.
Venturi Slow Suction is designed to apply negative pressure for the effective absorption of mucus from the patient’s lungs. At the same time, it supports the delivery of humidified oxygen, helping maintain patient comfort during suctioning procedures.
The Baby Bassinet features an innovative, integrated design developed to support the observation and transportation of neonates within clinical environments. Its construction enables caregivers to monitor infants comfortably while maintaining smooth mobility during routine transfers.
The Electrical Slow Suction unit is designed to provide controlled low-flow suction using negative pressure, making it ideal for gentle aspiration of fluids and secretions in respiratory management. Engineered for clinical workflows, this electrically powered system ensures consistent performance with quiet operation and dependable suction, supporting effective airway clearance in sensitive care settings.
Venturi Slow Suction is designed to apply negative pressure for the effective absorption of mucus from the patient’s lungs. At the same time, it supports the delivery of humidified oxygen, helping maintain patient comfort during suctioning procedures.
The Baby Bassinet features an innovative, integrated design developed to support the observation and transportation of neonates within clinical environments. Its construction enables caregivers to monitor infants comfortably while maintaining smooth mobility during routine transfers.
Designed with an integrated approach, the Infant Observation Trolley supports neonatal observation and transportation in a single, streamlined solution. Its clinical design enables caregivers to manage infants safely and efficiently within neonatal care environments.
The Oxygen Hood (Head Box) is engineered to deliver a controlled oxygen-rich environment for neonates, infants, and paediatric patients requiring respiratory support. Its clear, ergonomic design allows continuous patient observation while ensuring gentle and uniform oxygen administration for enhanced comfort and clinical confidence.
The Oxygen Hood (Head Box) is engineered to deliver a controlled oxygen-rich environment for neonates, infants, and paediatric patients requiring respiratory support. Its clear, ergonomic design allows continuous patient observation while ensuring gentle and uniform oxygen administration for enhanced comfort and clinical confidence.
nice 5050 – The Respiratory Monitor is designed to continuously monitor infant respiration using a highly sensitive pneumatic sensor attached to the baby’s chest or abdomen. The sensor detects even minute movements of the skin, enabling reliable identification of each respiration cycle or breath.
nice 4020 – The Phototherapy Radiometer accurately detects the therapeutic light intensity of the blue spectrum during neonatal phototherapy for hyperbilirubinemia. This battery-operated, portable device precisely measures irradiance and dosage levels delivered to the infant, ensuring effective treatment while remaining easy to transport and deploy across clinical settings.
nice 5040 – Engineered for dependable oxygen monitoring, the Oxygen Analyser employs an electrochemical sensor that delivers accurate, low-drift measurements with minimal power consumption. Its resistance to interfering gases and reliable detection performance make it a trusted, cost-effective solution for clinical oxygen concentration assessment.
nice 4050 – Fiber Optic Neonatal Transilluminator delivers high-intensity cool LED illumination for clear visualization of veins in neonates, infants, and pediatric patients. Designed to support accurate phlebotomy, the device enhances vein visibility through the skin, enabling faster and more confident bedside procedures.
nice 1050 – The Infantometer is designed for accurate measurement of an infant’s length from the top of the head to the heel. It features a large, smooth FRP base that provides a stable and comfortable surface for the baby during measurement. The one-sided sliding adjustment allows easy and precise positioning, ensuring consistent and reliable length measurement in clinical environments.
The infant weighing scale delivers precise and repeatable weight measurements critical for fluid management, medication dosing, and close monitoring of weight trends in neonates, including very low birth weight infants. Engineered for clinical accuracy, it supports confident, data-driven decision-making in demanding neonatal environments.
nice 1000 – The Infant Weighing Scale offers precise weight measurement with 5-gram accuracy, enabling reliable monitoring of even very low birth weight (VLBW) infants under 1.5 kg. Equipped with inbuilt height measurement, it allows easy tracking of growth patterns. Features like Tare and Zero functions ensure accurate weight readings without including accessories, while instantaneous measurement and a maximum capacity of 20 kg make it ideal for use in NICU and PICU settings. The scale operates on both AC and DC supply, providing flexibility and uninterrupted operation in critical care environments.
The Oxygen Pressure Regulator is a medical gas control device used to reduce the high pressure of oxygen supplied from a cylinder or central gas source to a stable and safe working pressure suitable for medical equipment. It ensures consistent oxygen delivery by maintaining a controlled outlet pressure, protecting downstream devices from pressure fluctuations or damage.
The Air Pressure Regulator is a medical gas control device used to reduce the high pressure of medical air supplied from a central gas source or compressor to a controlled and consistent outlet pressure suitable for medical equipment. It ensures reliable air delivery by maintaining stable pressure, protecting connected devices from pressure fluctuations.
The Bubble CPAP Flow Tube interfaces nasal masks/prongs with breathing circuits using a non-kinkable 10M 7mm ID corrugated tube and 10mm adaptor. Made of flexible, soft, biocompatible material with low flow resistance to minimize dead space. Fixing pillow (76-00-045) cushions sensitive newborn skin against tube compression.
The Acrylic Tray for Under Surface Phototherapy provides a stable and clear platform that enables uninterrupted light delivery from the phototherapy source placed beneath the infant. Its transparent design ensures minimal obstruction, supporting optimal exposure during treatment sessions.
Designed to support neonates during phototherapy, Cozy Gel provides a soft, transparent gel surface that enhances treatment efficiency while maintaining optimal comfort and skin protection.
nice 4060 Bili Flex wraps infants in high-intensity blue LED light delivered through biocompatible fiber optic pad, enabling continuous jaundice therapy during kangaroo mother care and transport. Variable intensity control and flexible cable design ensure comfortable positioning without heat interference. Optimized for preterm and low birth weight infants requiring mobile phototherapy solutions.
Resuscitation face masks are used for infant respiratory support and connect to circuits. They fit over the patient’s nose and are available in sizes 00, 0, and 1
Phototherapy Eye Pads are designed to protect an infant’s eyes during blue-light phototherapy treatment for jaundice. The pads block direct penetration of therapeutic blue light to prevent retinal exposure while ensuring comfort and safety.
Designed to reduce high cylinder pressure to a stable and safe outlet pressure in two stages, ensuring reliable oxygen delivery for respiratory applications such as Bubble CPAP, ventilators, and resuscitation systems.
Designed to reduce high cylinder pressure to a safe and usable outlet pressure for various respiratory applications. It delivers reliable oxygen supply for Bubble CPAP, ventilators, and resuscitation procedures.
The Air Intake Filter helps prevent dust, particles, and airborne contaminants from entering medical devices, supporting safe and efficient operation. By filtering incoming air, it protects internal components and contributes to consistent performance of neonatal and respiratory care equipment.
The Iris Port is designed to provide controlled access to the infant inside the incubator while maintaining stable thermal and humidity conditions. It enables caregivers to perform routine care and clinical procedures efficiently without fully opening the incubator canopy.
The Iris Port is designed to provide controlled access to the infant inside the incubator while maintaining stable thermal and humidity conditions. It enables caregivers to perform routine care and clinical procedures efficiently without fully opening the incubator canopy.
The Air Temperature Probe is designed to accurately measure the air temperature inside incubators and neonatal care environments. By providing real-time temperature feedback, it supports effective thermal regulation, helping maintain a stable and controlled microclimate essential for neonatal comfort and safety.
The Iris Port is designed to provide controlled access to the infant inside the incubator while maintaining stable thermal and humidity conditions. It enables caregivers to perform routine care and clinical procedures efficiently without fully opening the incubator canopy.
The Acrylic Tray for Under Surface Phototherapy provides a stable and clear platform that enables uninterrupted light delivery from the phototherapy source placed beneath the infant. Its transparent design ensures minimal obstruction, supporting optimal exposure during treatment sessions.
Designed to support neonates during phototherapy, Cozy Gel provides a soft, transparent gel surface that enhances treatment efficiency while maintaining optimal comfort and skin protection.
nice 4060 Bili Flex wraps infants in high-intensity blue LED light delivered through biocompatible fiber optic pad, enabling continuous jaundice therapy during kangaroo mother care and transport. Variable intensity control and flexible cable design ensure comfortable positioning without heat interference. Optimized for preterm and low birth weight infants requiring mobile phototherapy solutions.
Phototherapy Eye Pads are designed to protect an infant’s eyes during blue-light phototherapy treatment for jaundice. The pads block direct penetration of therapeutic blue light to prevent retinal exposure while ensuring comfort and safety.
Phototherapy Eye Pads are designed to protect an infant’s eyes during blue-light phototherapy treatment for jaundice. The pads block direct penetration of therapeutic blue light to prevent retinal exposure while ensuring comfort and safety.
The Bubble CPAP Flow Tube interfaces nasal masks/prongs with breathing circuits using a non-kinkable 10M 7mm ID corrugated tube and 10mm adaptor. Made of flexible, soft, biocompatible material with low flow resistance to minimize dead space. Fixing pillow (76-00-045) cushions sensitive newborn skin against tube compression.
Resuscitation face masks are used for infant respiratory support and connect to circuits. They fit over the patient’s nose and are available in sizes 00, 0, and 1
Maxflow Adult Nasal Cannula is engineered to provide high-flow oxygen therapy while maximizing patient comfort and clinical reliability. Designed for adult patients requiring sustained oxygen delivery, it supports faster recovery and helps reduce the need for invasive respiratory interventions.
High Flow Nasal Cannula is a non-invasive respiratory interface designed for preterm, neonatal, infant, and paediatric patients. It delivers precisely controlled, heated, and humidified air–oxygen mixtures at high flow rates to support spontaneous breathing during high flow oxygen therapy.
Available in XX Small (17-19 cm), X Small (19-21 cm), Small (21-23 cm), Medium (23-25.5 cm), Large (25.5-28 cm), X Large (28-30 cm), XX Large (30-33 cm), and XXX Large (33-36 cm), these bonnets feature open tops for ultrasound probe access without disruption.
Available in Small (98-00-133), Medium (98-00-134), Large (98-00-135), and X-Large (98-00-136), these masks feature anatomical curves that seal tightly over infant nares to prevent leaks during Bubble CPAP treatment. Soft silicone layers ensure smooth, irritation-free contact, while slots securely fix flow tubes and head bonnets for reliable positioning.
The Oxygen Pressure Regulator is a medical gas control device used to reduce the high pressure of oxygen supplied from a cylinder or central gas source to a stable and safe working pressure suitable for medical equipment. It ensures consistent oxygen delivery by maintaining a controlled outlet pressure, protecting downstream devices from pressure fluctuations or damage.
The Air Pressure Regulator is a medical gas control device used to reduce the high pressure of medical air supplied from a central gas source or compressor to a controlled and consistent outlet pressure suitable for medical equipment. It ensures reliable air delivery by maintaining stable pressure, protecting connected devices from pressure fluctuations.
The Bubble CPAP Flow Tube interfaces nasal masks/prongs with breathing circuits using a non-kinkable 10M 7mm ID corrugated tube and 10mm adaptor. Made of flexible, soft, biocompatible material with low flow resistance to minimize dead space. Fixing pillow (76-00-045) cushions sensitive newborn skin against tube compression.
Resuscitation face masks are used for infant respiratory support and connect to circuits. They fit over the patient’s nose and are available in sizes 00, 0, and 1
Phototherapy Eye Pads are designed to protect an infant’s eyes during blue-light phototherapy treatment for jaundice. The pads block direct penetration of therapeutic blue light to prevent retinal exposure while ensuring comfort and safety.
Available in XX Small (17-19 cm), X Small (19-21 cm), Small (21-23 cm), Medium (23-25.5 cm), Large (25.5-28 cm), X Large (28-30 cm), XX Large (30-33 cm), and XXX Large (33-36 cm), these bonnets feature open tops for ultrasound probe access without disruption.
The Air Pressure Regulator is a medical gas control device used to reduce the high pressure of medical air supplied from a central gas source or compressor to a controlled and consistent outlet pressure suitable for medical equipment. It ensures reliable air delivery by maintaining stable pressure, protecting connected devices from pressure fluctuations.
Resuscitation face masks are used for infant respiratory support and connect to circuits. They fit over the patient’s nose and are available in sizes 00, 0, and 1
Phototherapy Eye Pads are designed to protect an infant’s eyes during blue-light phototherapy treatment for jaundice. The pads block direct penetration of therapeutic blue light to prevent retinal exposure while ensuring comfort and safety.
Maxflow Adult Nasal Cannula is engineered to provide high-flow oxygen therapy while maximizing patient comfort and clinical reliability. Designed for adult patients requiring sustained oxygen delivery, it supports faster recovery and helps reduce the need for invasive respiratory interventions.
High Flow Nasal Cannula is a non-invasive respiratory interface designed for preterm, neonatal, infant, and paediatric patients. It delivers precisely controlled, heated, and humidified air–oxygen mixtures at high flow rates to support spontaneous breathing during high flow oxygen therapy.
Infant/Neonatal Breathing Circuit with Heated Wire for High Flow Oxygen Therapy (Combo kit)
The High Flow Oxygen Therapy breathing circuit is a patient gas delivery system designed to provide heated and humidified air–oxygen mixtures at high flow rates to neonates, infants, and paediatric patients with respiratory distress. It delivers a precise and controlled oxygen concentration at flow rates that meet or exceed the patient’s inspiratory demand.
Resuscitation face masks are used for infant respiratory support and connect to circuits. They fit over the patient’s nose and are available in sizes 00, 0, and 1
The Wall Mounting Bracket is a mechanical accessory designed to securely fix the air-oxygen blender onto a wall surface in clinical and hospital environments. It provides stable support, minimizing the risk of accidental movement, vibration, or detachment during normal operation. Its design supports efficient use of clinical space and organized equipment layout.
Pole Mounting Bracket holds air-oxygen blenders firmly to pole stands with multipoint contact for superior stabilization. Corrosion-free powder-coated aluminium provides ultra-lightweight yet sturdy support for heavy equipment loads.
The Oxygen Pressure Regulator is a medical gas control device used to reduce the high pressure of oxygen supplied from a cylinder or central gas source to a stable and safe working pressure suitable for medical equipment. It ensures consistent oxygen delivery by maintaining a controlled outlet pressure, protecting downstream devices from pressure fluctuations or damage.
Resuscitation face masks are used for infant respiratory support and connect to circuits. They fit over the patient’s nose and are available in sizes 00, 0, and 1
Phototherapy Eye Pads are designed to protect an infant’s eyes during blue-light phototherapy treatment for jaundice. The pads block direct penetration of therapeutic blue light to prevent retinal exposure while ensuring comfort and safety.
The Air Input Hose is a medical gas delivery accessory used to connect a medical air supply source, such as a central pipeline or compressor, to respiratory care equipment including air-oxygen blenders, ventilators, CPAP systems, and humidifiers. It ensures a reliable and continuous supply of medical air for proper device operation.
The Wall Mounting Bracket is a mechanical accessory designed to securely fix the air-oxygen blender onto a wall surface in clinical and hospital environments. It provides stable support, minimizing the risk of accidental movement, vibration, or detachment during normal operation. Its design supports efficient use of clinical space and organized equipment layout.
Pole Mounting Bracket holds air-oxygen blenders firmly to pole stands with multipoint contact for superior stabilization. Corrosion-free powder-coated aluminium provides ultra-lightweight yet sturdy support for heavy equipment loads.
The Rail Mounting Bracket is a mechanical accessory designed to securely attach the air-oxygen blender to standard medical equipment rails used in neonatal and critical care settings. It provides firm support to prevent accidental movement, vibration, or dislodgement of the blender during normal clinical use.
Designed for clinical reliability, the temperature probe delivers accurate and stable temperature sensing to support effective thermal management in neonatal and infant care environments. Its responsive sensing element ensures precise measurement, even with minimal temperature variation.
Designed for clinical reliability, the temperature probe delivers accurate and stable temperature sensing to support effective thermal management in neonatal and infant care environments. Its responsive sensing element ensures precise measurement, even with minimal temperature variation.
The Dual Heater Wire Adapter for Disposable Circuit enables precise and dependable connection of two heater wires within disposable circuit systems. Its purpose-built design ensures stable integration while supporting compact and efficient clinical setups
The Heater Wire Adapter for Disposable 3-Pin Circuit is designed to enable reliable connection of heater wires within disposable circuit configurations. Its application-specific design supports consistent integration while maintaining compatibility with 3-pin circuit interfaces.
Pole Mounting Bracket holds air-oxygen blenders firmly to pole stands with multipoint contact for superior stabilization. Corrosion-free powder-coated aluminium provides ultra-lightweight yet sturdy support for heavy equipment loads.
The Heater Wire Adapter for Disposable 2-Pin Circuit is designed to enable reliable connection of heater wires within disposable circuit configurations. Its application-specific design supports consistent integration while maintaining compatibility with 2-pin circuit interfaces.
The Air Intake Filter is engineered to ensure clean and reliable air entry into compressor by effectively filtering dust, particulates, and airborne impurities. Designed for integration with respiratory and critical-care equipment, it plays a vital role in maintaining optimal device performance and extending equipment life.
The Water Collector Bottle used in compressor systems is designed to trap and collect condensed moisture generated during air compression. By removing excess water from the compressed air, it helps prevent moisture from entering downstream equipment and patient delivery circuits, ensuring consistent and safe air supply.
The Air Input Hose is a medical gas delivery accessory used to connect a medical air supply source, such as a central pipeline or compressor, to respiratory care equipment including air-oxygen blenders, ventilators, CPAP systems, and humidifiers. It ensures a reliable and continuous supply of medical air for proper device operation.
Designed for clinical accuracy, the fiber optic cable delivers consistent and high-quality light transmission with minimal loss. Its advanced optical construction ensures dependable performance in demanding neonatal and medical applications where precision is essential.
The oxygen analyzer sensor is designed to accurately measure oxygen concentration in neonatal and clinical environments, supporting safe and effective respiratory care.
The disposable apnea respiratory sensor is designed for precise monitoring of neonatal and infant respiration by detecting subtle chest and abdominal movements. Its pneumatic sensor capsule, taped gently to the baby’s abdomen, accurately captures breathing cycles to support dependable apnea detection in clinical care environments.
The Pulse Oximeter Probe – Y Sensor is specially designed for neonatal and pediatric patients to measure blood oxygen saturation (SpO₂) and pulse rate with high accuracy. Its Y-shaped sensor design ensures proper alignment and optimal signal detection, supporting reliable monitoring even in low-perfusion conditions commonly seen in newborns.
The Pulse Oximeter Probe is designed to accurately measure blood oxygen saturation (SpO₂) and pulse rate, supporting continuous monitoring of a newborn’s respiratory and circulatory status. By providing real-time data, it helps caregivers quickly assess oxygen levels and respond promptly to clinical changes, ensuring safe and effective neonatal care.